ESSENTIAL DETAILS
MPX5050D vs MPX5700D vs MPX4250D vs MPX5999D vs XGZP6873A Comparison
Manufacturer | CFSensor | NXP | NXP | NXP | NXP |
Product Category | Pressure Sensor | Pressure Sensor | Pressure Sensor | Pressure Sensor | Pressure Sensor |
Series | XGZP6873A | MPX5050 | MPX5700 | MPX4250 | MPX5999 |
Model Number | As Order Guide | MPX5050D | MPX5700D | MPX4250D | MPX5999D |
Pressure Range | 0kPa~100kPa…1000kPa | 0KPa~50KPa | 0KPa~700KPa | 0KPa~250KPa | 0KPa~1000KPa |
Pressure Type | Differential | Differential | Differential | Differential | Differential |
Power Supply | 4.75V ~ 5.25V | 4.75V ~ 5.25V | 4.75V ~ 5.25V | 4.85V ~ 5.35V | 4.75V ~ 5.25V |
Output Type | Analog | Analog | Analog | Analog | Analog |
Output | 0.2 V ~ 4.7 V | 0.2 V ~ 4.7 V | 0.2 V ~ 4.7 V | 0.2 V ~ 4.9 V | 0.2 V ~ 4.7 V |
Accuracy | ±2.5% | ±2.5% | ±2.5% | ±1.5% | ±2.5% |
Measured Media | Air or Non-corrosive Gas | ||||
Temp. Compensated | Yes | Yes | Yes | Yes | Yes |
Operating Temp | -30~120°C | -40°C~125°C | -40°C~125°C | -40°C~125°C | -40°C~125°C |
Package | Pallets | Tray | Tray | Tray | Tray |
APPLICATIONS
- Medical&Healthy: e.g. ventilators, CPAP, NPWT, DVT, blood analysis, blood pressure monitoring, drug dosing, hospital beds, oxygen concentrators, patient monitoring, sleep apnea equipment, urine analyzers and wound therapy, breast pumps, massage device etc.
- Consumer&Household: e.g. Robot, UAV, wearable device, coffee makers, washing machines, vacuum cleaners, hand dryers, air pump, air beds, barometer,altimeter etc.
- Industrial&Automation: e.g. HVAC, process control and monitoring, engine control, level detectors, pressure switch and meter, IoT and automotive application etc.
INTRODUCTION
XGZP6873A is a prefect silicon pressure sensor offering a ratiometric analog interface for reading differential pressure over the specified full scale pressure span and temp.range.
The XGZP6873A incorporates a silicon piezoresistive pressure sensor chip and an interior signal-conditional Application Specific Integrated Circuit(ASIC) in a unibody package with long 6 PIN, which can be mounted freely from different direction.
The XGZP6873A is fully calibrated and temperature compensated for offset,sensitivity, temperature and non-linearity, so XGZP6873A pressure sensor satisfy the prefect repeatability,linearity, stability and sensibility, which can be applied directly in medical&healthy, home appliances, consumer electronic, industry, automotive, loT and other pneumatic devices etc.
XGZP6873A pressure sensor is for high volume application at an affordable cost and perfect performance. Customized calibrations(working voltage,output voltage,and pressure range) are available.
DIMENSION (Unit:mm)
ORDER GUIDE (100kPa=0.1MPa=1bar≈14.5PSI)
Note:
1. For specific output e.g 0.2~4.9V, signify output figure behind part number, e.g. : XGZP6873A250KPA0249
2. Custom requirement or parameter, please consult CFSensor for custom code(e.g custom pressure range etc,.)
PRESSURE RANGE EXAMPLE
Please consult CFSensor whether required pressure range is under normal production before place order.
Notes:
1. Unit conversion: 1000hPa=1000mbar≈750mmHg≈100kPa≈14.5PSI≈10mH2O≈1bar=0.1MPa;
2. Available for more custom pressure range e.g. 0~3.92kPa,-2~2kPa,0~6kPa, 0~25kPa etc,.
Datasheet: XGZP6873A Pressure Sensor V1.2.PDF